NOAA ERDDAP
Easier access to scientific data
| ?    
Brought to you by NOAA NMFS SWFSC ERD    
 
 
griddap Subset tabledap Make A Graph wms files Title Summary FGDC ISO 19115 Info Background Info RSS Email Institution Dataset ID
https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_acoustics_L0.subset https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_acoustics_L0 https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_acoustics_L0.graph https://data.obsea.es/erddap/files/OBSEA_seabed_station_acoustics_L0/ Acoustic recordings at OBSEA seabed station Acoustic recordings (FLAC files) at OBSEA seabed station from 2020-04-06 until now\n\ncdm_data_type = TimeSeries\nVARIABLES:\ntime (time of measurements, seconds since 1970-01-01T00:00:00Z)\ndepth (depth of measurements, m)\nlatitude (latitude of measurements, degrees_north)\nlongitude (longitude of measurements, degrees_east)\nsensor_id (Identifier of the sensor that took the measurement)\nplatform_id (Platform where the sensor was deployed)\nacoustics (underwater acoustics)\nNAXYS_SN0010 (Hydrophone NAXYS Ethernet 02345)\nOBSEA (OBSEA Expandable Seafloor Observatory (WMO number 6103565))\n https://data.obsea.es/erddap/metadata/fgdc/xml/OBSEA_seabed_station_acoustics_L0_fgdc.xml https://data.obsea.es/erddap/metadata/iso19115/xml/OBSEA_seabed_station_acoustics_L0_iso19115.xml https://data.obsea.es/erddap/info/OBSEA_seabed_station_acoustics_L0/index.htmlTable https://edmo.seadatanet.org/report/2150 (external link) https://data.obsea.es/erddap/rss/OBSEA_seabed_station_acoustics_L0.rss https://data.obsea.es/erddap/subscriptions/add.html?datasetID=OBSEA_seabed_station_acoustics_L0&showErrors=false&email= UPC - Universitat Politècnica de Catalunya OBSEA_seabed_station_acoustics_L0
https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1c.subset https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1c https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1c.graph https://data.obsea.es/erddap/files/OBSEA_seabed_station_SPL_L1c/ Sound Pressure Level time series at OBSEA seabed observatory (30min averages) Sound Pressure Level (SPL) time series derived from passive acoustic recordings at the OBSEA seabed observatory. Data are computed following Marine Strategy Framework Directive (MSFD) guidelines. SPL values are calculated in 1/3-octave bands (63 Hz, 125 Hz and 2 kHz) using 10-second time windows. Data is averaged every 30 minutes\n\ncdm_data_type = TimeSeries\nVARIABLES:\ntime (time of measurements, seconds since 1970-01-01T00:00:00Z)\ndepth (depth of measurements, m)\nlatitude (latitude of measurements, degrees_north)\nlongitude (longitude of measurements, degrees_east)\nsensor_id (Identifier of the sensor that took the measurement)\nplatform_id (Platform where the sensor was deployed)\nSPL_125 (Sound pressure level (SPL) of ambient noise at the 125Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_2000 (Sound pressure level (SPL) of ambient noise at the 2000Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_63 (Sound pressure level (SPL) of ambient noise at the 63Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_all (Sound pressure level (SPL) of ambient noise calculated using the hydrophone's full bandwidth with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap., dB)\nSPL_125_QC (Sound pressure level (SPL) of ambient noise at the 125Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_2000_QC (Sound pressure level (SPL) of ambient noise at the 2000Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_63_QC (Sound pressure level (SPL) of ambient noise at the 63Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_all_QC (Sound pressure level (SPL) of ambient noise calculated using the hydrophone's full bandwidth with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap. quality control flags)\nNAXYS_SN0010 (Hydrophone NAXYS Ethernet 02345)\nOBSEA (OBSEA Expandable Seafloor Observatory (WMO number 6103565))\n https://data.obsea.es/erddap/metadata/fgdc/xml/OBSEA_seabed_station_SPL_L1c_fgdc.xml https://data.obsea.es/erddap/metadata/iso19115/xml/OBSEA_seabed_station_SPL_L1c_iso19115.xml https://data.obsea.es/erddap/info/OBSEA_seabed_station_SPL_L1c/index.htmlTable https://edmo.seadatanet.org/report/2150 (external link) https://data.obsea.es/erddap/rss/OBSEA_seabed_station_SPL_L1c.rss https://data.obsea.es/erddap/subscriptions/add.html?datasetID=OBSEA_seabed_station_SPL_L1c&showErrors=false&email= UPC - Universitat Politècnica de Catalunya OBSEA_seabed_station_SPL_L1c
https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1b.subset https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1b https://data.obsea.es/erddap/tabledap/OBSEA_seabed_station_SPL_L1b.graph https://data.obsea.es/erddap/files/OBSEA_seabed_station_SPL_L1b/ Sound Pressure Level time series at OBSEA seabed observatory (quality-controlled) Sound Pressure Level (SPL) time series derived from passive acoustic recordings at the OBSEA seabed observatory. Data are computed following Marine Strategy Framework Directive (MSFD) guidelines. SPL values are calculated in 1/3-octave bands (63 Hz, 125 Hz and 2 kHz) using 10-second time windows.\n\ncdm_data_type = TimeSeries\nVARIABLES:\ntime (time of measurements, seconds since 1970-01-01T00:00:00Z)\ndepth (depth of measurements, m)\nlatitude (latitude of measurements, degrees_north)\nlongitude (longitude of measurements, degrees_east)\nsensor_id (Identifier of the sensor that took the measurement)\nplatform_id (Platform where the sensor was deployed)\nSPL_125 (Sound pressure level (SPL) of ambient noise at the 125Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_2000 (Sound pressure level (SPL) of ambient noise at the 2000Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_63 (Sound pressure level (SPL) of ambient noise at the 63Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\",, dB)\nSPL_all (Sound pressure level (SPL) of ambient noise calculated using the hydrophone's full bandwidth with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap., dB)\nSPL_125_QC (Sound pressure level (SPL) of ambient noise at the 125Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_2000_QC (Sound pressure level (SPL) of ambient noise at the 2000Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_63_QC (Sound pressure level (SPL) of ambient noise at the 63Hz-centered frequency band the with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap.\", quality control flags)\nSPL_all_QC (Sound pressure level (SPL) of ambient noise calculated using the hydrophone's full bandwidth with a time window of 10 seconds. The SPL values are computed using the Welch method with a time window of 10 seconds, using 1-second segments, Hann window and 50% overlap. quality control flags)\nNAXYS_SN0010 (Hydrophone NAXYS Ethernet 02345)\nOBSEA (OBSEA Expandable Seafloor Observatory (WMO number 6103565))\n https://data.obsea.es/erddap/metadata/fgdc/xml/OBSEA_seabed_station_SPL_L1b_fgdc.xml https://data.obsea.es/erddap/metadata/iso19115/xml/OBSEA_seabed_station_SPL_L1b_iso19115.xml https://data.obsea.es/erddap/info/OBSEA_seabed_station_SPL_L1b/index.htmlTable https://edmo.seadatanet.org/report/2150 (external link) https://data.obsea.es/erddap/rss/OBSEA_seabed_station_SPL_L1b.rss https://data.obsea.es/erddap/subscriptions/add.html?datasetID=OBSEA_seabed_station_SPL_L1b&showErrors=false&email= UPC - Universitat Politècnica de Catalunya OBSEA_seabed_station_SPL_L1b

 
ERDDAP, Version 2.24
Disclaimers | Privacy Policy | Contact